Technical information summary all other reagents, materials and equipment needed to perform the assay are used exclusively in the foundation medicine laboratory. Briefly, in a micro tube, rna probes were hybridized with hpv dna which had been denatured in a sample collection tube. Hybridcapture 2 assay has been the recommended method by the fda committee as a gold standard for diagnosis of hpv in clinical samples. Dec 10, 2018 in hybridcapture methods, the formation of probelibrary fragment dna duplexes are used to recover regions of interest. Principle of hybrid capture 2 hc2 technology qiagen. The assay is called hybrid capture hcwhole genome amplification wgaluminex lmx and is described as follows. Cellular heterogeneity affects the composite mrna ratio of samples. Pdf detection of human papillomavirus dna by the hybrid capture. A branched dna assay begins with a dish or some other solid support e. A secondgeneration commercial hpv test, the hybrid capture 2 hc2 assay, was introduced as a readytouse test for routine diagnostics and includes negative controls and positive controls pcs. The chosen targeted hybrid capture sequencing assay was further developed by adding target genes of interest figure 2a in accordance with the evolving literature. The dish is peppered with small, single stranded dna molecules or chains that stick up into the air. This document details the lab protocol for nhanes 20032004. Human papillomavirus testing with the hybrid capture 2 assay.
Human papillomavirus detection by the hybrid capture 2 hc2. Human papillomavirus testing with the hybrid capture 2. Proprietary blockers for dual and singleindex adapters, to reduce nonspecific adapter interaction during probe hybridization and increase ontarget capture performance. Hybridcapture based sequencing assays to detect novel. Targetenrichment strategy using hybrid capture was originally developed for human genomic studies for which it was used to capture and sequence the entire human exome. Briefly, hc2 is a signal amplification assay that uses a combination of antibody capture. The samples were analyzed for the presence of highriskhpv. Specifically, a sixperson working group of hematopathologists, clinicianoncologists, and translational scientists c. Part 2 of msc molecular diagnostics lecture on hybrid capture ii technology and hpv detection. En hybrid capture system rotary shaker 1 user manual. Such data will permit objective interpretation of this new procedure, and could contribute to cancer prevention. Human papilloma virus hybrid capture hybrid capture assay gynecologic screening specimen transport medium these keywords were added by machine and not by the authors. Frontiers hybrid capturebased next generation sequencing. The performance characteristics of pcr and the hc2 assay for testing for hpv have been compared, and the results have varied 2, 10, 14, 19, 24, 26.
Usefulness of hybrid capture hpv dna assay as a diagnostic. The hc2 highrisk hpv dna test using hybrid capture2 technology is a nucleic acid hybridization assay with. Rlu values are captured by assayspecific software on a dedicated computer attached to the luminometer. This process is experimental and the keywords may be updated as the learning algorithm improves. Briefly, hc2 is a signal amplification assay that uses a combination of antibody capture and chemiluminescent signal detection. The assay is using s1 nuclease, which degrades singlestranded dna and rna into oligo or mononucleotides, leaving intact doublestranded dna and rna. The flexible, fully customizable design accommodates up to 15 mb of. Detection of human papillomavirus dna by the hybrid capture assay. For highrisk hpv only the swabs were adequate using one of the laboratory tests digene hybrid capture ii, but both the tampon and swab were acceptable when a second test roche reverse line blot assay was used.
Clinical validation in the context of a hybrid capture. Assessment of capture and ampliconbased approaches for the. Comparing the cervista hpv hr test and hybrid capture 2. Nov 27, 2018 targetenrichment strategy using hybrid capture was originally developed for human genomic studies for which it was used to capture and sequence the entire human exome. Commonly used signal amplification technologies include branched dna bdna and hybrid capture hc assays. Qiagen, gmbh, hilden, germany, which detects dna of high. The capture assay was designed to capture 600 kb of target sequence which corresponded to 1. Crossreactivity profiles of hybrid capture ii, cobas, and. Abstractthe diagnostic performance of the widelyused cervista hpv hr test was compared to the hybrid capture 2 hc2. Lab medicine a proprietary system used to detect and monitor viraleg, chlamydia spp, cmv, hbv, hpv infections. The qiagen hc2 test is a sandwich capture molecular hybridization assay. Nextera rapid capture custom enrichment is an allinone assay for library preparation and custom target enrichment. Currently, human papillomavirus hpv dna tests validated in large trials and epidemiological studies are the hybrid capture secondgeneration hc2 hpv dna assay and a variety of polymerase chain reaction pcr protocols.
For simulating a mutation at a specific position, start and end bed coordinates should denote that exact same position. Foundationfocus cdxbrca technical information summary. The hybrid capture 2 hc2 system hpv dna test by digene by brenda palacios objectives state the 2 main lowrisk hpv dna types state the 2 main highrisk hpv dna types state what type of test method is used for the detection of hpv state the minimum sample volume required for testing state what the molecular sandwich consist of human papillomavirus hpv primary. The hpv tests included the hybrid capture tube test hct, the microplatebased hybrid capture ii test hc ii, and the my09my11 l1 consensus primer pcrbased assay. The nuclease hybridization assay, also called s1 nuclease cutting assay, is a nuclease protection assay based hybridization elisa. The hybrid capture 2 hc2 highrisk hpv dna assay serves as a triage test in the slovenian national cervical cancer screening programme zora. In hybridcapture methods, the formation of probelibrary fragment dna duplexes are used to recover regions of interest.
Hybrid capturebased human papillomavirus detection versus pcr. The hc2 highrisk hpv dna test using hybrid capture2 hc2 technology is a nucleic acid hybridization assay with signal amplification using microplate chemiluminescence for the qualitative detection of thirteen highrisk types of human papillomavirus hpv dna in cervical specimens. The foundationfocus cdxbrca assay uses a customdeveloped analysis pipeline to identify brca12 base substitutions and short insertiondeletions indels up to bp. Human papillomavirus detection by the hybrid capture 2. Highlights this hpv mrna hybridcapture assay has use in hpv transcription studies. In the sandwich hybridization elisa assay format, the antigen ligand and antibodies in elisa are replaced with a nucleic acid analyte, complementary oligonucleotide capture and detection probes generally, in the case of nucleic acid hybridization, monovalent salt concentration and temperature are controlled for hybridization and wash stringency, contrary to a traditional. Dec, 2014 first year medical students from philadelphila college of osteopathic medicine georgia campus d. Evaluation of the hybrid capture assay for determination of. To improve the limited analytical accuracy of hc2 test results near the cutoff value 1. Comparative study between the hybrid capture ii test and.
The hybrid capture 2 hc2 system hpv dna test by digene by brenda palacios objectives state the 2 main lowrisk hpv dna types state the 2 main highrisk hpv dna types state what type of test method is used for the detection of hpv state the minimum sample volume required for testing state what the molecular sandwich consist of human papillomavirus hpv primary etiological agent in cervical. Hybridcapture article about hybridcapture by the free. Comparison with hybrid capture i and pcr results in cervical lesions. Chapter 7 methods for detection of hpv infection and its clinical. Hpv genotype detection using hybrid capture sample. Screen captures are only one feature of the software. The digene highrisk hpv dna test using hybrid capture. Evaluation of the hybrid capture assay for determination. First year medical students from philadelphila college of osteopathic medicine georgia campus d. Hybrid capture assay, version hc2 digene, gaithersburg, md, usa which is able to detect. First, there is a sequencespecific sample enrichment process to isolate singlestranded hpv dnas while removing much of the nonspecific genomic dna that may interfere with some assays.
The performance characteristics of hcii assay and the pcr for detection of hpv dna have been compared in cervical lesions and results shown variation. Hpv dna testing by the hcii assay method was performed with the automated hcii assay system located in the department of pathology, universiti sains malaysia, according to the protocol of the manufacturer. The pdf24 creator then takes the screen capture and creates a pdf file. Sample size and no longitudinal arm limited the clinical assessment of assay. Targeted enrichment by solutionbased hybrid capture to. The analytical performance for in vitro rna and cultured cells was satisfactory. Hybrid capture assay the hybrid capture assay was performed according to the directions of the manufacturer. Optimizing the hybrid capture ii human papillomavirus test. Evaluation of polymerase chain reaction pcr method and. Successful hybrid capturebased next generation sequencing ngs is influenced by a range of parameters including probe design efficiency, ontarget coverage, uniformity of coverage, analytical sensitivity and specificity, library complexity, amount of dna input required, scalability, reproducibility, ease of use, and overall cost. The aptima hpv assay versus the hybrid capture 2 test in. Print bookmark share pdf 1880kb english format file size language download get adobe reader. Molecular diagnostics of human papillomavirus laboratory. Recentaly, a secondgeneration assay with improved diagnostic sensitivity has been developed known as hybrid capture ii test hcii and approved by the us food and drug administration fda.
Thednarnahybridsarecapturedon amicroplate,andtheemittedlightismeasuredinaluminometerasrela. Pdf detection of human papillomavirus dna by the hybrid. Detection of human papillomavirus dna by the hybrid capture assay article pdf available in brazilian journal of infectious diseases 72. Hybrid capture 2 hc2 highrisk hpv dna test digene catalog number 51011296 for in vitro diagnostic use a nucleic acid hybridization microplate assay with signal amplification for the chemiluminescent detection of human papillomavirus hpv types 16,18,31,33,35,39,45,51,52,56,58,59 and 68 in cervical specimens reagents for 96 tests.
Clinical validation in the context of a hybrid capturebased. Hybrid capture definition of hybrid capture by medical. Amplificationbased methods have excellent specificity and uniformity. Hybrid capture assay definition of hybrid capture assay. The assistant opens, where you can save or choose to do something else with the new file. Hybrid capture ii residual swabs were kept at 4c in thinprep test bottles. Hybrid capture 2 hc2 technology serves as the platform for qiagens nucleic acid hybridization assay for detection of human papillomavirus hpv. Pdf evaluation of the digene hybrid capture ii assay. Free fulltext pdf articles from hundreds of disciplines, all in one place crossreactivity profiles of hybrid capture ii, cobas, and aptima human papillomavirus assays. The original hybrid capture assay hc1 was approved by the fda in 1995. What is the process for capturing rna or dna cells lysed, rnases inactivated, attached to tube are multiple targetspecific probes, sample rna binds to these capture probes, amplification occurs as several sets of probes bind to target andor each other. Assessment of capture and ampliconbased approaches for. The assay is called hybrid capture hc whole genome amplification wgaluminex lmx and is described as follows.
Comparison of onclarity human papillomavirus hpv assay. These values are downloaded to an excel file for data storage and subsequent file transport to westat. This document details the lab protocol for nhanes 2003. The hybrid capture assay is a standardized assay that is simple to perform and can utilize whole blood specimens that have been stored for up to 48 h. Get a printable copy pdf file of the complete article 680k, or click on a page.
Hybrid capture assay definition of hybrid capture assay by. The original hybrid capture assay hc1 was approved by. In addition, printed copies of each assay, together with quality control calculations, are stored in notebooks. Sep 24, 2019 the hybrid capture 2 hc2 highrisk hpv dna assay serves as a triage test in the slovenian national cervical cancer screening programme zora. While wes has proven useful for diagnosis and management in specific clinical situations, selected gene panels have more utility at lower cost. Hybrid capture article about hybrid capture by the free. Sep 23, 2010 recentaly, a secondgeneration assay with improved diagnostic sensitivity has been developed known as hybrid capture ii test hcii and approved by the us food and drug administration fda. Nextera tagmentation coupled with optimized target capture ensures the fastest enrichment workflow time for custom content. This assay uses a nucleic acid hybridisation assay where the samples with the target dna. Screen capture to pdf capture your screen as a pdf file. Dec 01, 2016 part 2 of msc molecular diagnostics lecture on hybrid capture ii technology and hpv detection.
An in vitro nucleic acid hybridization assay with signal amplification using microplate chemiluminescence for the qualitative detection of human papillomavirus hpv types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59 and 68 in cervical specimens. The digene hc2 hpv dna test using hc2 technology is a signal amplified hybridization antibody capture assay that. En hybrid capture system rotary shaker 1 user manual qiagen. Comparative study between the hybrid capture ii test and pcr. Class of 2018 get together to utilize active learning an. Clinical relevance of the borderline results of the hybrid. Optimized buffers, cot dna, and streptavidin beads for use with xgen lockdown probes and panels in hybrid capture target enrichment. Using the illumina hiseqtm 4000 platform, hybridcapture selected libraries are sequenced to uniform depth targeting 500x coverage with 99% of exons at coverage 100x. Hybrid capture ii, a new sensitive test for human papillomavirus. The foundationfocus cdxbrca assay is intended to be performed with serial numbcontrolled er instruments. Comparing the cervista hpv hr test and hybrid capture 2 assay. Hybrid capture is a signal amplification technique, meaning that the chemiluminescent or fluorescent signal is amplified to aid detection, rather than the target dna being amplified by pcr. This genomic technique, also called exome sequencing or whole exome sequencing was first applied by using an arraybased hybrid capture method in 2007 hodges et al.
Chr 8 point mutation indel a a a a a a a a a a a chr 10 hybrid capturebased ngs technology parallel detection of point mutations, indels, copy number changes and gene fusions reliable analysis also on small amounts of material. Multicenter comparison of the digene hybrid capture cmv dna assay version 2. The only procedure that may be capable of recognizing all. To implement the larger 2400 gene panel, we utilized a different target. Mutations are introduced at the midpoints of the bed coordinates.
699 1461 383 129 474 949 263 370 1400 1277 788 1153 745 976 413 890 380 1266 1405 992 172 1189 711 279 598 254 1005 540 14 1133 1027 1272 1007 546 22 92